MEASUREMENT
CERTIFICATE - 2nd edition X-99
- ISAF RECOGNIZED CLASS Feb
2000 |
YARD´S
DECLARATION: This
X-99 did comply with the X-99 International Class Rules - 1998 Edition while leaving the
yard in respect of following subparagraphs: 3.1
- 3.2 - 3.5 - 3.6 - 3.8 - 4.1 - 4.2 - 4.3 - 4.4 - 4.5 - 5.1 - 5.2 - 5.3 - 5.5 - 6.1 - 6.2
- 6.3 - 6.4 - 6.5 - 6.6 - 7.1 - 7.2 - 7.3 - 7.4 - 8.1 - 9.1 - 9.2 - 9.4 - 9.5 - 9.6 - 10.1
- 15 15.1 - 15.2 - 15.3 - 15.4 - 15.5 - 15.6 - 16.1 - 16.2 - 17.1 - 17.2 - 17.3 - 17.5 -
17.6 Date
:____________ Yard´s
representative:___________________________ |
X-99
HULL NO
YEAR OF DEPARTURE FROM YARD: |
REGISTERED
KEEL CASTING WEIGHT: (boats built after 1998) |
ENGINE
MAKE, MODEL
ENGINE DRY WEIGHT |
|
OWNER´S
DECLARATION: I
undertake to race this X-99 only as long as I maintain it strictly in accordance with the
valid class rules Date
:____________
Owner´s signature:___________________________ |
YACHT´S
NAME:
YACHT CLUB: |
YACHT´S
FIRST
SAIL NO:
YACHT´S CURRENT SAIL NO: |
OWNER´S
NAME:
STREET/NO |
ZIPCODE:
TOWN:
COUNTRY:
ELEC. ADDRESS/TEL |
e-mail
address. |
APPOINTED
MEASURER´S NAME, ADDRESS , TEL - STAMP.
REGISTERED BY NATIONAL SAILING
FEDERATION _________________________________ _________________________________ _________________________________ _________________________________ _________________________________ (To
be appointed by the National. X-99 Club or the National Sailing Federation) |
MEASURER´S
DECLARATION: I
have checked or measured according to following forms, enclosed this cover page: (Form A is
mandatory, Forms B & C are advsory) A)
X-99
Measurement Form for Weights
(dated March 1997) B)
X-99
Measurement Form for Mast & Rig
(dated February 2000) C)
X-99
Measurement Form for Sails
(dated February 2000) Date:______________
Measurer´s signature:_________________________________ |
(backside
of Measurement Certificate)
Change
of Ownership
New
Owner´s Name:________________________________________________________
New
Owner´s Address:______________________________________________________
_________________________________________________________________________
_________________________________________________________________________
NEW OWNER´S
DECLARATION: I
undertake to race this X-99 only as long as I maintain it strictly in accordance with the
valid class rules Date
:____________
Owner´s signature:___________________________ |
New
Owner´s Name:________________________________________________________
New
Owner´s Address:______________________________________________________
_________________________________________________________________________
_________________________________________________________________________
NEW OWNER´S DECLARATION: I
undertake to race this X-99 only as long as I maintain it strictly in accordance with the
valid class rules Date
:____________
Owner´s signature:___________________________ |
New
Owner´s Name:________________________________________________________
New
Owner´s Address:______________________________________________________
_________________________________________________________________________
_________________________________________________________________________
NEW OWNER´S
DECLARATION: I
undertake to race this X-99 only as long as I maintain it strictly in accordance with the
valid class rules Date
:____________
Owner´s signature:___________________________ |
A) X-99 Measurement Form for Weights
|
B)
X-99 ISAF RECOGNIZED CLASS -
MEASUREMENT FORM FOR MAST & RIG - Feb 2000 This
measurement form is not mandatory to be filled and shall only be filled out when control
measurement has been carried out. |
|||||||
MAST
& RIG
Covered by Yards declaration |
|||||||
|
Rule
no |
What
to be measured |
INITIALS |
MAX (mm) |
MIN (mm) |
Notes |
Actual
measurement |
|
6.2 |
Distance mast section
to forstay at deck level |
J |
3450 |
3435 |
|
|
|
|
Mast
profile length |
MPL |
140 |
136 |
|
|
|
|
Mast
profile width |
MPW |
94 |
90 |
|
|
|
|
Taper
length |
TL |
2100 |
|
|
|
|
|
Taper
top profile length |
TPL |
|
80 |
|
|
|
|
Taper
top profile width |
|
|
60 |
|
|
|
6.3 |
Dist
between the black bands |
P |
12500 |
|
|
|
|
6.4 |
Boom
above sheerline |
BAS |
1600 |
1580 |
|
|
|
|
Boom
above base mast |
BABM |
2790 |
2770 |
|
|
|
9.2 |
Forestay
height above lower P-band |
IG
above lower P band |
9665 |
9625 |
See rigplan drawing no 3 |
|
|
6.5 |
Spinn
halyard height related to forestay height |
ISP<=IG |
|
|
See rigplan drawing no 3 |
|
|
6.6 |
Top
spreader length |
TSL |
530 |
510 |
6290 +/- 300 mm above lower P-band |
|
|
|
Lower
spreader length |
LSL |
860 |
840 |
2540 +/- 300 mm above lower P-band |
|
BOOM
Covered by Yards declaration |
|||||||
|
7.1 |
Boom
depth |
BD |
140 |
|
|
|
|
7.2 |
Boom
length |
E |
4500 |
|
Black band distance to aft side mast profile |
|
SPINNAKER
POLE
Covered
by Yards declaration |
|||||||
|
8.1 |
Spinn
pole length |
SPL |
3450 |
|
|
|
STANDING
RIGGING
Covered by Yards declaration |
|||||||
|
9.4 |
Forestay
diameter |
|
6 |
5
- see note |
5 mm Dalform or Dyeform may be fitted |
|
|
|
Running
backstay - diameter |
|
5 |
5 |
|
|
|
|
Permanent
backstay - diameter |
|
4 |
4 |
|
|
|
|
Cap
shrouds - diameter |
|
6 |
6 |
|
|
|
|
Intermediate
shrouds - diameter |
|
4 |
4 |
|
|
|
|
Lower
shrouds - diameter |
|
6 |
6 |
|
|
|
|
Checkstays
- diameter |
|
4 |
4 |
|
|
DATE:
MEASURERS NAME AND SIGNATURE
|
|||||||
X-99
- ISAF RECOGNIZED
CLASS - MEASUREMENT FORM FOR SAILS - Feb 2000 |
|||||||
MAINSAIL
(Min
cloth weight 260 m2) |
|||||||
|
Rule-no |
WHAT
TO MEASURE |
INITIALS |
MAX (mm) |
MIN (mm g/m2) |
NOTES |
ACTUAL
MEASUREMENT |
|
11.6 |
Headboard |
HB |
160 |
|
|
|
|
11.9 |
Leech
length |
|
13200
|
|
|
|
|
11.10 |
Upper
girth |
MGU |
1650 |
|
See
Rule |
|
|
11.10 |
Middle
girth |
MGM |
2800 |
|
See
Rule |
|
|
11.11 |
Top
batten |
BL1 |
1500 |
|
All
battens evenly distributed over the length of the leech |
|
|
11.11 |
Upper
Middle batten |
BL2 |
1500 |
|
All
battens max width 52 mm |
|
|
11.11 |
Lower
Middle batten |
BL3 |
1500 |
|
|
|
|
11.11 |
Lower
batten |
BL4 |
1100 |
|
|
|
|
11.12 |
Reef
1 Leech |
|
|
1000 |
See
Rule for closer definition |
|
|
11.12 |
Reef
2 leech |
|
|
3200 |
|
|
|
11.15 |
Window
|
|
|
|
Max
size 0.32 m2 - not within 200 mm of leech |
|
GENOA
1
(Min
cloth weight 140 g/m2) |
|||||||
|
11.16 |
Foot
length |
|
no
limit |
no
limit |
To
be recorded for checking girth lengths |
|
|
11.16 |
Top
girth |
|
Foot
x 0.25 |
|
Girth
length of genoa at 3/4 height of both luff and leech |
|
|
11.16 |
Middle
girth |
|
Foot
x 0.5 |
|
Girth
length of genoa at _ height of both luff and leech |
|
|
11.16 |
Lower
girth |
|
Foot
x 0.75 |
|
Girth
length of genoa at 1/4 height of both luff and leech |
|
|
11.17 |
Luff
length |
Tmax |
11500 |
|
|
|
|
11.16 |
Luff
Perpendicular |
LP |
5170 |
|
If
forestay profile is used, max LP shall be reduced by the double value of the width of the
profile -see rule 11.16 |
|
GENOA
III
(Min cloth weight 310 g/m2) |
|||||||
|
11.16 |
Foot
length |
|
No
limit |
no
limit |
To
be recorded for checking girth lengths |
|
|
11.16 |
Top
girth |
|
Foot
x 0.25 |
|
Girth
length of genoa at 3/4 height of both luff and leech |
|
|
11.16 |
Middle
girth |
|
Foot
x 0.5 |
|
Girth
length of genoa at _ height of both luff and leech |
|
|
11.16 |
Lower
girth |
|
Foot
x 0.75 |
|
Girth
length of genoa at 1/4 height of both luff and leech |
|
|
11.18 |
Luff
perpendicular |
LP |
3350 |
|
Battens
allowed - top batten full length Lower 2 battens max 500 mm |
|
|
11.19 |
Luff
length |
Tmax |
11500 |
|
|
|
|
|
|
|
|
|
|
|
MAX
SPINNAKER |
|||||||
|
11.21 11.22 |
Leech
length |
SL |
11200 |
|
Min
cloth weight 40 g/m2 |
|
|
|
Foot
length |
SF |
6350 |
|
|
|
|
|
Max
width |
SMW |
8400 |
|
|
|
REACHING
SPINNAKER |
|||||||
|
11.21
11.23 |
Leech
length |
SL |
11200 |
|
min
cloth weight 40 g/m2 |
|
|
|
Foot
length |
|
6200 |
5900 |
|
|
|
|
Width
at 1/2 height |
|
6200 |
5900 |
|
|
DATE:
MEASURER´S NAME AND SIGNATURE
|
|||||||
|
|||||||